R&S®ESCI EMI Test Receiver

For compliance tests meeting all civil standards from 9 kHz to 3 GHz

Characteristics

The R&S ESCI is backed by decades of experience gained by Rohde & Schwarz in the development of test receivers and spectrum analyzers. The test receiver's advanced design concept offers the following characteristics:

Frequency range 9 kHz to 3 GHz
Preselection 11 preselection filters
can be switched off in analyzer mode
Resolution bandwidths (receiver and analyzer mode)
3 dB bandwidths 10 Hz to 3 MHz, in steps of 1/3/10
6 dB bandwidths 200 Hz, 9 kHz, 120 kHz acc. to CISPR 16 tolerance
Pulse bandwidth 1 MHz
FFT filters 1 Hz to 30 kHz, in steps of 1/3/10
Channel/RRC 44 filters between 100 Hz and 5 MHz
Displayed average noise level (DANL)
Receiver mode; 0 dB RF attn.; preamp. 20 dB
9 kHz to 150 kHz (RBW 200 Hz) –15 to –20 dBμV
0.15 MHz to 30 MHz (RBW 9 kHz) –4 to –14 dBμV
30 MHz to 1000 MHz (RBW 120 kHz) <–4 dBμV
1 GHz to 3 GHz (RBW 1 MHz) <6 dBμV
Intermodulation
1 dB compression point of input mixer
f > 200 MHz; 0 dB RF attn.;
preamp. + presel. off
5 dBm nominal
Total level uncertainty
without preselection/preamplifier ≤0.5 dB
with preselection/preamplifier ≤1.0 dB
Measurement speed
Sweep (analyzer mode) 1 µs to 16.000 s (zero span); resolution 125 ns
2.5 ms to 16.000 s (span ≥ 10 Hz)
Scan (receiver mode) 100 μs to 100 s (selectable)
Max. input level
RF attn. ≥ 10 dB; CW RF power 30 dBm
Max. pulse voltage (10 μs)
RF attn. ≥ 10 dB 150 V

Example of DANL measurement (from acceptance test report)

Example of TOI measurement (from acceptance test report)